Structural performance on bolted sleeved connections between two CFS channel sections subjected to combined bending and shear

natesan, vijayakumar and Madhavan, Mahendrakumar (2019) Structural performance on bolted sleeved connections between two CFS channel sections subjected to combined bending and shear. Structures, 20. pp. 794-812. ISSN 23520124

Full text not available from this repository. (Request a copy)

Abstract

An experimental investigation was carried out to study the behavior of the sleeve connection between two cold-formed steel (CFS) channel sections subjected to combined bending and shear. A total of thirty-nine specimens including three control specimens were tested under three-point bending for different parameters such as three types of the span to section depth ratio, three different sleeve lengths, two sleeve thicknesses and two bolt configurations. Each tested specimen consisted of a pair of channel sections braced together using hot rolled angle sections along the length to ensure lateral stability. The test results indicate two different failure modes; local buckling due to combined bending and shear in the purlin section adjacent to sleeve end, and the other is shearing of the self-drilling screw at the tension zone. The moment resistance of the sleeve connection varied directly with the sleeve length to section depth ratio. The interaction study carried out between the proposed critical sleeve moment and shear capacity of the sleeve specimens is found to be conservative with respect to the AISI interaction equation. The resistance factor for load and resistance factor design (LRFD) method and safety factor for allowable strength design (ASD) method is proposed for the design of sleeve connection by considering it as a flexural member. The design uniformly distributed load (wD) of sleeve specimens having an average sleeve length to section depth ratio of 2.17, 3.51, and 4.85 are found to be 80, 103, and 125% the capacity corresponding to control specimen respectively. The proposed design method is also applicable to the design of continuous channel purlin/girt sections with 150 mm depth for any number of spans subjected to UDL.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Madhavan, MahendrakumarUNSPECIFIED
Item Type: Article
Uncontrolled Keywords: Bolted sleeve connection, CFS channel, Local buckling, Moment –rotation, Moment resistance, Reliability study
Subjects: Civil Engineering
Divisions: Department of Civil Engineering
Depositing User: Team Library
Date Deposited: 29 Jul 2019 04:31
Last Modified: 29 Jul 2019 04:31
URI: http://raiith.iith.ac.in/id/eprint/5816
Publisher URL: http://doi.org/10.1016/j.istruc.2019.06.026
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 5816 Statistics for this ePrint Item