Robust and accurate personalised reconstruction of standard 12-lead system from Frank vectorcardiographic system

Maheshwari, S and Acharyya, Amit and Puddu, P E and Mazomenos, E B and Schiariti, M and Maharatna, K (2016) Robust and accurate personalised reconstruction of standard 12-lead system from Frank vectorcardiographic system. Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization, 4 (3-4). pp. 183-192. ISSN 2168-1163

Full text not available from this repository. (Request a copy)

Abstract

In this article, we have proposed a robust and accurate method for the reconstruction of standard 12-lead (S12) system from Frank vectorcardiographic (FV) system using personalised transformation (PT) matrices targeting personalised remote health monitoring applications. FV system is used in the 3D visualisation of heart and diagnosis and prognosis of many cardiologic disorders including myocardial infarction, Brugada syndrome etc. However, cardiologists are accustomed to S12 system pertaining to its decades-old usage and widespread acceptability and hence, it is generally used as primary ECG acquisition system and state-of-the-art inverse Dower transform (DT) and affine transform (AT) are used to obtain FV system from S12 system. Here, we propose the acquisition of FV system and use PT to reconstruct S12 system from FV system. PhysioNet's PTB database after wavelet-based preprocessing to remove baseline wandering and noise has been used in this investigation. The personalised coefficients have been obtained using least-squares fit method and heart-vector projection theory and evaluation metrics used are R-2 statistics, correlation and regression coefficients. Our proposed PT methodology has outperformed AT and DT by mean R-2 values of 16.36% and 26.53%, respectively. For the practical application of the proposed system, we have investigated into the reusability of personalised coefficients which has been shown to outperform state-of-the-art AT and DT.

[error in script]
IITH Creators:
IITH CreatorsORCiD
Acharyya, Amithttp://orcid.org/0000-0002-5636-0676
Item Type: Article
Uncontrolled Keywords: Frank VCG system; personalised coefficients; lead reconstruction; ECG; standard 12-lead system
Subjects: Others > Electricity
Divisions: Department of Electrical Engineering
Depositing User: Team Library
Date Deposited: 26 Jul 2016 05:20
Last Modified: 29 Aug 2017 10:51
URI: http://raiith.iith.ac.in/id/eprint/2584
Publisher URL: https://doi.org/10.1080/21681163.2014.931029
OA policy: http://www.sherpa.ac.uk/romeo/issn/2168-1163/
Related URLs:

Actions (login required)

View Item View Item
Statistics for RAIITH ePrint 2584 Statistics for this ePrint Item